Lovato Expansion Modules & Accessories

Lovato Electric

Expansion Modules & Accessories

The Lovato Range of Expansion Modules and Accessories for Compatible Products

Lovato expansion modules and related accessories are compatible with Lovato products of various applications, including: power quality, control, metering and remote monitoring. Expansion modules allow for adaptable products that can be custom tailored to specific job requirements when the need arises.

Many Lovato Products are also compatible with the Lovato software line (Synergy, Xpress, Sam1 & NFC), which can be used to interface with Lovato products, for remote supervision and to program/set parameters using PCs, tablets and smartphones. Click here to learn more about the Lovato software range.

 

General Characteristics:

EXP Series Expansions –
• Rear base product mounting with no need of tools.
• Powered directly by the base product.
• Automatic identification by the base product.
• For flush mount products.
• T suffixed versions have tropicalised PCB.
• Digital inputs.
• Relay outputs.
• Static outputs.
• Analog inputs.
• Inputs for PT100 temperature sensor.
• Thermocouple inputs “J” or “K” types.
• Analog outputs.
• Communication interface.
• GPRS/GSM modem.
• Data storage.

 

EXM Series Expansions – 
• For modular products.
• Base product connection via IR (infrared beam) port.
• Automatic identification by the base product.
• Side base product mounting.
• Digital inputs.
• Relay outputs.
• Static outputs.
• Communication interface.
• Data storage.

 

Communication Devices – 
• Communication devices to link Lovato products to PC’s, Smartphones and Tablets.
CX01 – This USB/optical dongle, complete with cable, enables the connection of compatible Lovato products with a PC without having to disconnect the power supply from the electrical panel. The PC identifies the connection as a standard USB.
• CX02 – This Wi-Fi point connection, lets Lovato products be viewed by a PC, smartphone and tablet without having to connect cables.

 

EXC RDU 1 Remote Display Unit – 
• Alarm conditions can be viewed on the remote display and alarm silencing can also be activated.
• Dual 100…240VAC / 12…24VDC power supply.
• Touch screen 128×112 pixel back-lit graphic LCD.
• Built-in buzzer.
• Static (SSR) output for global alarm signalling.
• Opto-isolated RS485 interface port.
• Conductor cross section: 0.2…2.5mm squared (24…12 AWG; 18…12 AWG per UL/CSA).
• Tightening torque: 0.56Nm (4.5lbin).
• Compatible with ADXL… soft starter and VLB3… variable speed drives.

 

RGK RR Alarm Status Relay Unit – 
• An expansion unit for remoting statuses and alarms. RGK RR can be connected at a maximum distance of 1000m using the static output of the ATL900. RGK RR has 12 output relays, 7 normally open, and 5 changeover contacts.

 

Protective Covers – 
• If high IEC degree of protection is required, protective covers can provide the necessary IP rating.
• PA 96X48 – Front IP65 protective cover for multi-meters DMK 0/1…
• 31 PA96X96 – Front IP54 protective cover for multi-meters DMK 2…

 

EXC CON 01 Converter – 
• The EXC CON 01 converter can interface “Slave” devices connected in a RS485 bus with a “Master” equipped with an Ethernet interface port.
• Kit consisting of a converter and DIN rail mounting accessory.
• Web interface programming.
• No power pack included.

 

EXC M3G 01 Gateway – 
• The EXC M3G 01 gateway can interface “Slave” devices connected in a RS485 with a “Master” using a 3G network.
• Connection TCP server through 3G or 2G network.
• Transparent mode: data is transferred from the 3G side to the serial side and vice versa without protocol conversion.
• Settable parameters: TCP server IP and remote port, network operator apn (with username and password), SIM card pin (with enabling), connection time-out, serial parameters (baud rate from 1,200 bps to 115,200 bps, stop bit, character length, parity).
• RJ45 port for programming parameters and diagnostics with simple software tool.
• Antenna compatible with a major part of world-wide mobile networks, due to the 850/900/1800/1900/2100 MHz frequencies. IEC degree of protection: IP67. Fixing by 10mm diameter drilling. Cable length = 2.5m.

 

EXC GL A01 & EXC GL AX1 Gateway – 
• EXC GL A01 gateway is able to collect data from devices which are connected through Ethernet or RS485 port. Modbus RTU, ASCII and TCP protocols are supported. The data can be reviewed by a connection to the Lovato Synergy Cloud service or to Ethernet local web server and a browser. The access to internet for sending data can be achieved by either Ethernet port or with a Lovato EXC GL AX1 2G/3G modem.
• CPU ARM 1 GHz.
• 2 Ethernet ports.
• 1 RS232/RS485 serial port.
• 24VDC (10…32VDC) power supply.
• Operating Temperature: -20…+60 degrees Celsius.
• Simplified connection to other Lovato devices.
• Compatible with Lovato Synergy and Synergy Cloud software.

 

Connecting Cables – 
• Connecting cables to link Lovato devices to PCs, modems and bus converters.

 

See the following links to view the expansion module/product Compatibility Tables:

 

Order Code Description
EXP Inputs and Outputs:
EXP1000  4 digital inputs, opto-isolated.
EXP1001  4 static outputs, opto-isolated.
EXP1002  2 digital inputs and 2 static outputs, opto-isolated.
EXP1003  2 relay outputs, rated 5A 250VAC
EXP1004  2 analog inputs, opto-isolated 0/4…20mA, PT100, 0-10V 0r 0…+/- 5V.
EXP1004T  2 analog inputs, opto-isolated 0/4…20mA, PT100, 0-10V 0r 0…+/- 5V, PCB tropicalised.
EXP1005  2 analog outputs, opto-isolated 0/4…20mA, 0-10V or 0…+/- 5V.
EXP1006  2 relay outputs to increase number of steps.
EXP1007  3 relay outputs to increase number of steps.
EXP1008  2 opto-isolated digital inputs and 2 relay outputs rated 5A  250VAC.
EXP1008T  2 opto-isolated digital inputs and 2 relay outputs rated 5A  250VAC, PCB tropicalised.
EXP1040  2 digital/resistive inputs, 2 static outputs.
EXP1041  2 thermocouple inputs, 2 static outputs.
EXP1042T  6 digital inputs, PCB tropicalised.
EXP1043T  4 digital inputs and 2 static outputs, PCB tropicalised.
EXP Communication Ports:
EXP1010  Opto-isolated USB interface.
EXP1011  Opto-isolated RS232 interface.
EXP1012  Opto-isolated RS485 interface.
EXP1012T  Opto-isolated RS485 interface, PCB tropicalised.
EXP1013  Opto-isolated Ethernet interface with Web server function.
EXP1013T  Opto-isolated Ethernet interface with Web server function, PCB tropicalised.
EXP1014  Opto-isolated Profibus-DP interface.
EXP Various Functionalities:
EXP1016  Capacitor bank protection.
EXP1030  Data storage, clock-calendar.
EXP1031  Data storage, clock-calendar with Energy Quality (EN 50160).
EXM Inputs and Outputs:
EXM1000  2 digital inputs and 2 static outputs, opto-isolated.
EXM1001  2 digital inputs, opto-isolated and 2 relay outputs rated 5A 250VAC.
EXM1002  4 opto-isolated digital inputs and 2 relay outputs rated 5A 250VAC.
EXM Communication Ports:
EXM1010  Opto-isolated USB interface.
EXM1011  Opto-isolated RS232 interface.
EXM1012  Opto-isolated RS485 interface.
EXM1013  Opto-isolated Ethernet interface.
EXM1020  Opto-isolated RS485 interface and 2 relay outputs, rated 5A 250VAC.
EXM1030  Data storage, RTC with backup reserve energy for data logging.
Accessories:
EXP8000  Plastic insert for customising label for DMG 600/610/611 and DCRL…
EXP8001  IP65 140mm gasket seal for ATL600/610/611 and DCRL8.
EXP8003  35mm DIN rail mounting accessory for ADXL… soft starter.
EXP8004  Fan for ADXL… soft starter.
EXM8004  Set of sealable terminal covers for DMG 100/101/110/200/210/300.
EXP8005  IP65 110mm housing gasket, for RGK 4…SA.
NTC01  External/remote temperature sensor, with 3m long cable.
Communication Devices:
CX01  PC to Lovato product dongle, with USB optic connector for programming, data download, diagnostics and firmware upgrade.
CX02  PC to Lovato product Wi-Fi dongle for programming, data download, diagnostics and firmware upgrade.
Remote Display/ Alarm Status Relay Unit:
EXCRDU1  Remote display unit, graphic LCD, touch screen 128 x 112 pixels, IP65 protection. Compatible with ADXL… soft starter and VLB3… variable speed drives.
RGKRR  Alarms-status relay unit, 12/24VDC, 12 relay outputs, pulse input, CANbus communication port.
Protective Covers:
PA96X48  Front IP65 protective cover for multimeters DMK 0/1…
31PA96X96  Front IP54 protective cover for multimeters DMK2…
Converters:
EXCCON01  RS485/ Ethernet converter, 12…48VDC, including DIN rail fixing kit.
4PX1  RS232/RS485 converter, galvanically isolated, supply 220…240VAC (or 110…120VAC).
Gateways:
EXCM3G01  RS485 Gateway/3G modem, 9.5…27VAC / 9.5…35VDC, including antenna and programming cable.
EXCGLA01  Gateway data logger for data collecting via Modbus from the devices in the field. Publishing of the data to supervision software, also in Cloud.
EXCGLAX1  2G/3G modem communication module for EXC GL A01.
Connecting Cables:
51C2  For PC to Lovato device, 1.8m long.
51C3  For PC to GSM Modem, 1.8m long.
51C4  For PC to RS232/RS485 converter drive, 1.8m long.
51C5  For Analog Modem to Lovato device, 1.8m long.
51C7  For GSM Modem to Lovato device, 1.8m long.
51C8  For ADX to remote keypad, 3m long.