RTLX Input Line Reactors

Polylux RTLX Input Line Reactors

 

Polylux RTLX Input Line Reactors for AC Drives

 

  • Operational Characteristics:

– Three phase line reactors for AC drives.
– Reduces drive generated harmonics.
– Rated currents from 2.5-1000A.
– Thermal over temperature protection.
– Custom designs available.
– Rated Voltage: Line voltage 480-460V 50/60Hz.
– Isolation: Class F – 155°C.
– Winding: Class HC- 200°C.
– Thermal Overload Factor: 5%.
– Voltage Drop: 4% at 400V 50Hz and nominal current.
– Test Voltage: 3kV (1 min, 50Hz).
– Protection: IP00.
– Temp Rating: +40°C.
– Temperature Rise: <90°C.
– Connection: Terminals or lugs.
– Construction: Aluminium windings.
– Standards: IEC/EN/UNE-EN 60076-6, CE.

 

Order Code Rated Current (A) @40°C Motor Rating (kW)  L (mH) Dimensions
A x B x C (mm) 
 Weight (kg)
18RTLX025 2.5 0.75 11.762 120 x 74 x 107 1.4
18RTLX040 4 1.1 7.351 120 x 74 x 107 1.4
18RTLX050 5 1.5 5.881 120 x 74 x 107 1.6
18RTLX063 6.3 2.2 4.667 120 x 74 x 107 1.9
18RTLX080 8 3 3.676 120 x 84 x 107 2.3
18RTLX100 10 4 2.941 120 x 84 x 107 2.7
18RTLX160 16 5.5 1.838 150 x 135 x 185 5.1
18RTLX200 20 7.5 1.470 150 x 140 x 185 5.9
18RTLX250 25 11 1.176 150 x 145 x 185 6.5
18RTLX315 31.5 15 0.933 150 x 155 x 185 7.9
18RTLX400 40 18.5 0.735 150 x 165 x 185 9.2
18RTLX500 50 22 0.588 180 x 150 x 220 10.6
18RTLX630 63 30 0.467 180 x 155 x 220 11.6
18RTLX800 80 37 0.368 180 x 165 x 220 13.7
18RTLX1000 100 45 0.294 180 x 205 x 220 20.7
18RTLX1250 125 55 0.235 180 x 185 x 220 22.8
18RTLX1600 160 75 0.184 180 x 207 x 220 26.1
18RTLX2000 200 90 0.147 240 x 173 x 290 32.8
18RTLX2500 250 110-132 0.118 240 x 188 x 290 38.5
18RTLX3150 315 160 0.093 340 x 234 x 375 46.5
18RTLX4000 400 185-200 0.074 340 x 254 x 375 57
18RTLX5000 500 220-250 0.059 340 x 289 x 375 74
18RTLX6300 630 280-315 0.047 360 x 371 x 525 102
18RTLX8000 800 370-400 0.037 360 x 381 x 525 115
18RTLX10000 1000 450-500 0.029 360 x 421 x 525 142

(Please see attached PDF’s for further information)