RTLX Input Line Reactors

Polylux RTLX Input Line Reactors

 

Polylux RTLX Input Line Reactors for AC Drives

 

  • Operational Characteristics:

– Three phase line reactors for AC drives.
– Reduces drive generated harmonics.
– Rated currents from 2.5-1000A.
– Thermal over temperature protection.
– Custom designs available.
– Rated Voltage: Line voltage 480-460V 50/60Hz.
– Isolation: Class F – 155°C.
– Winding: Class HC- 200°C.
– Thermal Overload Factor: 5%.
– Voltage Drop: 4% at 400V 50Hz and nominal current.
– Test Voltage: 3kV (1 min, 50Hz).
– Protection: IP00.
– Temp Rating: +40°C.
– Temperature Rise: <90°C.
– Connection: Terminals or lugs.
– Construction: Aluminium windings.
– Standards: IEC/EN/UNE-EN 60076-6, CE.

 

Order CodeRated Current (A) @40°CMotor Rating (kW) L (mH)Dimensions
A x B x C (mm) 
 Weight (kg)
18RTLX0252.50.7511.762120 x 74 x 1071.4
18RTLX04041.17.351120 x 74 x 1071.4
18RTLX05051.55.881120 x 74 x 1071.6
18RTLX0636.32.24.667120 x 74 x 1071.9
18RTLX080833.676120 x 84 x 1072.3
18RTLX1001042.941120 x 84 x 1072.7
18RTLX160165.51.838150 x 135 x 1855.1
18RTLX200207.51.470150 x 140 x 1855.9
18RTLX25025111.176150 x 145 x 1856.5
18RTLX31531.5150.933150 x 155 x 1857.9
18RTLX4004018.50.735150 x 165 x 1859.2
18RTLX50050220.588180 x 150 x 22010.6
18RTLX63063300.467180 x 155 x 22011.6
18RTLX80080370.368180 x 165 x 22013.7
18RTLX1000100450.294180 x 205 x 22020.7
18RTLX1250125550.235180 x 185 x 22022.8
18RTLX1600160750.184180 x 207 x 22026.1
18RTLX2000200900.147240 x 173 x 29032.8
18RTLX2500250110-1320.118240 x 188 x 29038.5
18RTLX31503151600.093340 x 234 x 37546.5
18RTLX4000400185-2000.074340 x 254 x 37557
18RTLX5000500220-2500.059340 x 289 x 37574
18RTLX6300630280-3150.047360 x 371 x 525102
18RTLX8000800370-4000.037360 x 381 x 525115
18RTLX100001000450-5000.029360 x 421 x 525142

(Please see attached PDF’s for further information)